‧AC‧M172SAP (C7)

172x150x51mm/6.8x5.9x2inch
310CFM
Sinwan AC Metal Impeller, High Performance
  Rated
Volt
Voltage
Range
Freq Input
Power
Ref.
Speed
Max.Airflow Max.Static Pressure Noise
Level
PQ UL
Model No VAC VAC Hz Watt

RPM

CFM m3/min Inch/H2O mm db(A)    
M172SAP11-1** (C7) 115 100~120 50/60 47/42 2850/3300 280/310 7.9/8.8 0.69/0.74 17.53/18.8 61 2/1 £
M172SAP11-2** (C7) 115 100~120 50/60 35/32 2400/2500 230/240 6.5/6.8 0.63/0.65 16/16.51 52 4/3 £
M172SAP22-1** (C7) 230 200~240 50/60 47/42 2850/3300 280/310 7.9/8.8 0.69/0.74 17.53/18.8 61 2/1 £
M172SAP22-2** (C7) 230 200~240 50/60 35/32 2400/2500 230/240 6.5/6.8 0.63/0.65 16/16.51 52 4/3 £
M172SAP11/22-1** (C7)
dual voltage
115
230
100~120
200~240
50/60 47/42 2850/3300 280/310 7.9/8.8 0.69/0.74 17.53/18.8 61 2/1 £
M172SAP11/22-2** (C7)
dual voltage
115
230
100~120
200~240
50/60 35/32 2400/2500 230/240 6.5/6.8 0.63/0.65 16/16.51 52 4/3 £
M172SAP38-1** (C7) 380 380~420 50/60 47/42 2850/3300 280/310 7.9/8.8 0.69/0.74 17.53/18.8 61 2/1 £
M172SAP44-1** (C7) 440 440~480 50/60 47/42 2850/3300 280/310 7.9/8.8 0.69/0.74 17.53/18.8 61 2/1 £
-Optional Function Leads:

*Tachometer,speed sensor pulses 5V, input 4.5~27 VDC,
1 signal each revolution, or 2 signals each revolution available on request. Function-F/G
*Alarm output signals for abnormal or normal available on request. Function-R/D

  • 100, 200, 240V or special voltages 12, 24, 28, 38, 42, 48, 380~440~480... 50/60Hz, & dual voltage version available on request.
  • Dual speed High/Medium 1/2, High/Low 1/3, Medium/Low 2/3, Low/extra Low 3/4 or triple speed 1/2/3 available on request.
  • Sinwan reserves the right to change data and improve electrical or mechanical design without notice, data tolerance +-10%
  •  
      Motor Type: Capacitor induction
      Burnout Protection: Thermally protected
      IP Protection: IP55
      Frame: Aluminum die-cast, black color treatment
      Impeller: All metal fan blades design
      Bearing: Two high precision permanently lubricated ball bearings
      Rotation: CCW looking at rotor, air inlet side of housing
      Connection: Wire leads or push-in terminal pin connecting for option
      Weight: 800 g (1.32 Lbs)
      Dielectric Strength: Over 1 minute at 1,500 VAC, 0.5mA, 50/60 Hz
      Insulation Resistance: Over 100 Mega Ohm at DC 500V
      Signal Output: Optional:R/D alarm output, tachometer output F/G
      Operating Temp: Ambient non-condensing -30C~+75C
      Storage Temp: -40~+100C (at 65%RH)
      Life Expectancy: MTBF Formula L10 indoor life test 120K hours at 35C, 45K hours at 60C

     

    Metal Fan Guard
    G172-10H


    Plastic Fan Guard
    G172P


    Plastic Fan Filter
    GRM172-30


    Metal Fan Screen
    MF172S-30N