‧DC‧
MED280GAN
Dia.89x85mm/3.5x3.3inch
70~120Watt max.
 
  Rated
Voltage
Voltage
Range
Rated
Loading
Input
Ref.
Loading
Speed
No Loading Free Running Starting No Load UL
Input Current Speed Voltage Input Current  
Model No VDC VDC Watt RPM

Watt

Amp RPM VDC Watt Amp  
MED280GAN12-HB** 12 12~13.8 120~110 2600 13 1.08 4450 7 2.4 0.2 £
MED280GAN12-MB** 12 12~13.8 90~85 2200 13 1.08 4440 7 2.4 0.2 £
MED280GAN12-LB** 12 12~13.8 65~55 1800 14 1.16 4440 8 2.4 0.2 £
MED280GAN24-HB** 24 18~27.6 120~110 2700 13 0.54 4450 11 2.4 0.1 £
MED280GAN24-MB** 24 18~27.6 90~85 2200 14 0.58 4440 11 2.4 0.1 £
MED280GAN24-LB** 24 18~27.6 90~85 1800 14 0.58 4430 12 2.4 0.1 £
MED280GAN48-HB** 48 24~53 120~110 2600 13 0.27 4450 17 2.4 0.05 £
MED280GAN48-MB** 48 24~56 90~85 2200 14 0.29 4440 17 2.45 0.05 £
MED280GAN48-LB** 48 24~56 65~55 1800 14 0.29 4430 18 2.4 0.05 £
  • **= DC / DR / UC / UR / DUC / DUR / NC / NR, for full model No. click “Nomenclature”.
    First *=D, U, DU, N description of shaft outlet position, second *=C, R description of motor rotating direction C-CW , R-CCW.
    Example: MED280GAN12-HBDR, **/DR= Shaft outlet- D type, motor rotating direction viewed from rotor CCW-R type
  • Sinwan reserves the right to change data and improve electrical & mechanical design without notice, data tolerance +-10%
  •  
      Motor Type: Microprocessor programmable CPU controlled brushless DC, locked rotor & polarity protected
      IP Protection: IP55 optional request
      Frame: Aluminum diecasting, mounting holes dia.3.2mm self tapping or tapped M4
      Bearing: Two high precision permanently lubricated ball bearings
      Shaft: Stainless steel SUS420J2,dia.8mm,50mm out.Customer's design available
      Weight: 1350Gm(2.98 Lb)
      Dielectric Strength: Over 1 sec. at 500VAC, maximum leakage 500 micro Amp.
      Insulation Resistance: Over 10 mega Ohm at DC 500V between leads and frame
      Speed Control: PWM, S/C NTC thermister, S/V (0~10V) speed control on request
      Operating Temp: Acceptable -25°C~+65°C. Storage -30°C~+90°C (65%RH)
      Life Expectancy: 60K hours at 45°C, 30K hours at 60°C. MTBF life 100K hours at 55°C