‧AC‧SBK800EAN

Dia.84x41mm / 3.3inch
33~14 CFM
Plastic Impeller
  Rated
Volt
Voltage
Range
Freq Input
Power
Ref.
Speed
Max.Airflow Max.Static Pressure Noise
Level
PQ UL
Model No VAC VAC Hz Watt

RPM

CFM m3/min Inch/H2O mm db(A)    
SBK800EAN-11-1 115 100~120 50/60 20/18 2550/2800 29/33 0.8/0.9 0.42/0.50 10.67/12.7 48 £
SBK800EAN-11-2 115 100~120 50/60 14/12 2300/2150 25/23 0.7/0.7 0.35/0.33 8.89/8.38 39 £
SBK800EAN-11-3 115 100~120 50/60 11/9 1500/1650 11/13 0.3/0.4 0.18/0.19 4.57/4.83 28 £
SBK800EAN-22-1 230 200~240 50/60 20/18 2550/2800 29/33 0.8/0.9 0.42/0.50 10.67/12.7 47 £
SBK800EAN-22-2 230 200~240 50/60 14/12 2300/2150 25/23 0.7/0.7 0.35/0.33 8.89/8.38 39 £
SBK800EAN-22-3 230 200~240 50/60 11/9 1500/1650 11/13 0.3/0.4 0.18/0.19 4.57/4.83 28 £
SBK800EAN-11/22-1
dual voltage
115
230
100~120
200~240
50/60 20/18 2550/2800 29/33 0.8/0.9 0.42/0.50 10.67/12.7 48 £
  • The stated airflow, air pressure, noise levels are measured with housing orifice dia.: impeller Φ +1~1.5mm, at distance: approx. height of impeller + motor frame. The optimal operating data can only be depended on the installation conditions.
  • ** = "WB" for wire lead type Ball bearing, or "TB" for terminal type Ball bearing
  • 100, 200, 240V or special voltages 12, 24, 28, 38, 42, 48, 380~440~480... 50/60Hz, & dual voltage version available on request.
  • Dual speed High/Medium 1/2, High/Low 1/3, Medium/Low 2/3, Low/extra Low 3/4 or triple speed 1/2/3 available on request.
  • Sinwan reserves the right to change data and improve electrical or mechanical design without notice, data tolerance +-10%
  •  
      Motor Type: Shaded pole induction
      Burnout Protection: Impedance protected
      IP Protection: IP44
      Frame: Aluminum diecasting , 7 mounting holes dia.2.3mm or tapped M3
      Impeller: Glass fiber reinforced PBT thermoplastic impeller, UL94V-0
      Bearing: Two ball bearings
      Rotation: CW seen on rotor
      Connection: Wire lead
      Weight: 360Gm (0.8 Lb)
      Dielectric Strength: Over 1 min.at 1,500 VAC, 0.5mA, 50/60 Hz
      Insulation Resistance: Over 100 MΩ at DC 500V
      Signal Output: -
      Operating Temp: Ambient non-condensing -20~+80C
      Storage Temp: -40C~+100C (at 65%RH)
      Life Expectancy: 55K hours at 45°C, 25K hours at 65°C based on life test Formula L10