‧AC‧MK938

Dia.85x39mm / 3.5inch
55~27 CFM
Metal Impeller
  Rated
Volt
Voltage
Range
Freq Input
Power
Ref.
Speed
Max.Airflow Max.Static Pressure Noise
Level
PQ UL
Model No VAC VAC Hz Watt

RPM

CFM m3/min Inch/H2O mm db(A)    
MK938AN11-1** 115 100~120 50/60 17/15 2700/3150 45/55 1.3/1.6 0.17/0.22 4.32/5.59 33 £
MK938AN11-2** 115 100~120 50/60 13/11 2350/2600 36/42 1/1.2 0.14/0.16 3.56/4.06 24 £
MK938AN11-3** 115 100~120 50/60 9/7 1950/1850 29/27 0.8/0.8 0.12/0.11 3.05/2.79 20 £
MK938AN22-1** 230 200~240 50/60 17/15 2700/3150 45/55 1.3/1.6 0.17/0.22 4.32/5.59 33 £
MK938AN22-2** 230 200~240 50/60 13/11 2350/2600 36/42 1/1.2 0.14/0.16 3.56/4.06 24 £
MK938AN22-3** 230 200~240 50/60 9/7 1950/1850 39/27 1.1/0.8 0.12/0.11 3.05/2.79 20 £
MK938AN11/22-1**
dual voltage
115
230
100~120
200~240
50/60 17/15 2700/3150 45/55 1.3/1.6 0.17/0.22 4.32/5.59 33 £
MK938AN2-1** 12 12~14 50/60 17/15 2700/3150 45/55 1.3/1.6 0.17/0.22 4.32/5.59 33 £
MK938AN4-1** 24 24~28 50/60 17/15 2700/3150 45/55 1.3/1.6 0.17/0.22 4.32/5.59 33 £
MK938AN6-1** 28 28~34 50/60 17/15 2700/3150 45/55 1.3/1.6 0.17/0.22 4.32/5.59 33 £
MK938AN8-1** 48 48~58 50/60 17/15 2700/3150 45/55 1.3/1.6 0.17/0.22 4.32/5.59 33 £
MK938AN38-1** 380 380~420 50/60 17/15 2700/3150 45/55 1.3/1.6 0.17/0.22 4.32/5.59 33 £
MK938AN44-1** 440 440~480 50/60 17/15 2700/3150 45/55 1.3/1.6 0.17/0.22 4.32/5.59 33 £
  • The stated airflow, air pressure, noise levels are measured with housing orifice dia.: impeller Φ +1~1.5mm, at distance: approx. height of impeller + motor frame. The optimal operating data can only be depended on the installation conditions.
  • ** = "WB" for wire lead type Ball bearing, or "TB" for terminal type Ball bearing
  • 100, 200, 240V or special voltages 12, 24, 28, 38, 42, 48, 380~440~480... 50/60Hz, & dual voltage version available on request.
  • Dual speed High/Medium 1/2, High/Low 1/3, Medium/Low 2/3, Low/extra Low 3/4 or triple speed 1/2/3 available on request.
  • Sinwan reserves the right to change data and improve electrical or mechanical design without notice, data tolerance +-10%
  •  
      Motor Type: Shaded pole induction, 1-phase
      Burnout Protection: Impedance protected
      IP Protection: IP55
      Frame: Aluminum die cast, natural color treatment Optional: Black cosmetics
      Impeller: Steel metal fan blades integrantly spot welded into rotor for high efficiency
      Bearing: Two high precision permanently lubricated ball bearings
      Rotation: CCW seen on rotor
      Connection: Wire lead
      Weight: -
      Dielectric Strength: Over 1 minute at 1,500 VAC, 0.5mA, 50/60 Hz
      Insulation Resistance: Over 100 MΩ at DC 500V
      Signal Output:
      Operating Temp: Ambient non-condensing -30~+80C
      Storage Temp: -40C~+100C (at 65%RH)
      Life Expectancy: 55K hours at 45°C, 25K hours at 65°C based on life test Formula L10