‧AC‧SB800AP

126x126x41mm
32~10 CFM
  Rated
Volt
Voltage
Range
Freq Input
Power
Ref.
Speed
Max.Airflow Max.Static Pressure Noise
Level
PQ UL
Model No VAC VAC Hz Watt

RPM

CFM m3/min Inch/H2O mm db(A)    
SB800AP-11-1** 115 100~120 50/60 20/18 2600/2800 29/32 0.8/0.9 0.44/0.52 11.18/13.21 49 2/1 £
SB800AP-11-2** 115 100~120 50/60 14/12 2000/2100 22/23 0.6/0.7 0.33/0.34 8.38/8.64 37 4/3 £
SB800AP-11-3** 115 100~120 50/60 11/9 1500/1400 11/10 0.3/0.3 0.17/0.15 4.32/3.81 29 6/5 £
SB800AP-22-1** 230 200~240 50/60 20/18 2600/2800 29/32 0.8/0.9 0.44/0.52 11.18/13.21 49 2/1 £
SB800AP-22-2** 230 200~240 50/60 14/12 2000/2100 22/23 0.6/0.7 0.33/0.34 8.38/8.64 37 4/3 £
SB800AP-22-3** 230 200~240 50/60 11/9 1500/1400 11/10 0.3/0.3 0.17/0.15 4.32/3.81 29 6/5 £
SB800AP-11/22-1**
dual voltage
115
230
100~120
200~240
50/60 20/18 2600/2800 29/32 0.8/0.9 0.44/0.52 11.18/13.21 49 2/1 £
  • ** = "WB" for wire lead type Ball bearing, or "TB" for terminal type Ball bearing
  • 100, 200, 240V or special voltages 12, 24, 28, 38, 42, 48, 380~440~480... 50/60Hz, & dual voltage version available on request.
  • Dual speed High/Medium 1/2, High/Low 1/3, Medium/Low 2/3, Low/extra Low 3/4 or triple speed 1/2/3 available on request.
  • Sinwan reserves the right to change data and improve electrical or mechanical design without notice, data tolerance +-10%
  •  
      Motor Type: Shaded pole induction, inner rotor, 1-phase
      Burnout Protection: Impedance protected
      IP Protection:
      Frame: Aluminum die-cast, black color cosmetics
      Impeller: Glass fiber reinforced plastic, rated UL94V-0
      Bearing: Two ball bearings
      Rotation: CW seen on rotor
      Connection: Wire lead
      Weight: 630 g (1.4 Lbs)
      Dielectric Strength: Over 1 min. at 1,500 VAC, 0.5mA, 50/60 Hz
      Insulation Resistance: Over 100 MΩ at DC 500V
      Signal Output: Optional:R/D alarm output, tachometer output
      Operating Temp: Ambient non-condensing -20~+75C
      Storage Temp:
      Life Expectancy: L10 85K hours at +45C, 40K hours at +60C